Online Encyclopedia

Search over 40,000 articles from the original, classic Encyclopedia Britannica, 11th Edition.

ELECTRICAL

Online Encyclopedia
Originally appearing in Volume V26, Page 833 of the 1911 Encyclopedia Britannica.
Spread the word: del.icio.us del.icio.us it!

ELECTRICAL See also:

THERMOMETRY 21. The convenience of the See also:mercurial thermometer lies in the fact that it is See also:complete in itself, and can be read without subsidiary appliances beyond a magnifying See also:glass. Its weakness lies in the very limited range of each single See also:instrument, and in the troublesome and often uncertain corrections which must be applied to its readings in all See also:work of precision. Electrical thermometers have the disadvantage of requiring See also:auxiliary apparatus, such as galvanometers and resistances, the use of which involves some electrical training. But they far surpass the mercurial thermometer in point of range, delicacy and adaptability, and can be applied to many investigations in which See also:ordinary thermometers are quite useless. There are two kinds of electrical thermometers, which depend on different effects of See also:heat on the electrical properties of metals: (r) The Thermocouple, or Thermopile, which depends on the See also:production of a thermoelectric force when the junctions of different metals in an electric See also:circuit are at different temperatures; and (2) the Electrical Resistance Thermometer, the See also:action of which depends on the fact that the resistance of a pure See also:metal to the passage of an electric current increases very considerably when the temperature is raised. The theory of the thermocouple is discussed in the See also:article See also:THERMOELECTRICITY, as it possesses many points of See also:interest, and has been studied by many skilful experimentalists. The electrical resistance thermometer is of more See also:recent origin; but although the theory has been less fully See also:developed, the practice of the method bids See also:fair to surpass all others in the variety and accuracy of its applications. In See also:order to secure the widest possible range and the greatest constancy, in either variety of electrical thermometer, See also:advantage is taken of the See also:great stability and infusibility characteristic of the metals of the See also:platinum See also:group. Other metals are occasionally used in work at See also:low temperatures with thermocouples for the See also:sake of obtaining a larger electromotive force, but the substitution is attended with loss of constancy and uncertainty of reduction, unless the range is greatly restricted. 22. Applications of the Thermocouple.—The See also:principal uses of the thermocouple in thermometry are for measuring high temperatures, and for measuring small See also:differences of temperature, more particularly when the temperature is required to be measured at a point, or in a very small space.

The electromotive force of the couple depends only on the temperature at the See also:

plane of junction of the two metals, which can be very exactly located. A typical instance of a measurement to which the thermocouple is peculiarly suited, is the determination of the cyclical See also:variations of temperature at accurately measured depths from one-tenth to one-hundredth of an See also:inch in the metal of the See also:cylinder of a heat See also:engine, the interior See also:surface of which is exposed to cyclical variations of temperature in the working of the engine). The exact See also:depth of the plane of junction can be measured without difficulty to the thousandth of an inch. The insertion of the See also:wire makes the least possible disturbance of the continuity of the metal. There is no lag, as the thermometer itself is See also:part of the metal. The instantaneous value of the temperature at any particular point of the stroke can be measured separately by setting a periodic contact to See also:close the circuit of the See also:galvanometer at the desired point. A further advantage is gained by measuring only the difference of temperature between two junctions of a thermocouple at different depths, instead of the whole See also:interval from some fixed point. None of these advantages could be secured by the use of any ordinary thermometer; some depend on the fact that the method is electrical, but some are See also:peculiar to the thermocouple, and could not be otherwise attained. On the other See also:hand, the thermocouple is not well suited for thermometry of precision on See also:account of the smallness of the electromotive force, which is of the order of ten microvolts only per degree for the most See also:constant couples. By the use of very delicate galvanometers it is possible to read to the hundredth or even in See also:special cases to the thousandth of a degree on this small difference, but unfortunately it is not possible to eliminate accidental thermal effects in other parts of the circuit due to small differences of temperature and material. These accidental effects seldom amount to less than one or two microvolts even in the best work, and limit the accuracy attainable in temperature measurement to about the tenth of a degree with a single platinum thermocouple. This limit can be surpassed 1 See also:Hall, Trans.

Amer. Inst. Elect. Eng. 1891, vol. viii. p. 226; Callendar and See also:

Nicolson, Prot. Inst. C. E. vol. cxxxi. p. 1.by using couples of greater thermoelectric See also:power and less permanence, or by using a See also:pile or See also:series of couples, but in either See also:case it is doubtful whether the advantage gained in power is not balanced by loss of simplicity and constancy. A method of avoiding these effects, which the writer has found to be of great use in delicate thermoelectric researches, is to make the whole circuit, including all the terminals and even the slide-wire itself, of pure See also:copper. Platinoid, See also:german See also:silver, constantan and other See also:alloys most commonly used for resistances and slide-wires, are particularly to be avoided, on account of their great thermoelectric power when connected to copper.

Manganin and platinum-silver are the least objectionable, but the improvement effected by substituting copper is very marked. It is clear that this objection to the use of the couple does not apply so strongly to high temperatures, because the electromotive force of the couple itself is greater, and the accuracy attainable is limited by other considerations. 23. The Resistance Thermometer.—In practice the resistance thermometer is almost invariably made of platinum, since there is very seldom any advantage to be gained by the substitution of baser metals. The instrument is for this See also:

reason often referred to simply as the " platinum thermometer." It is important that the platinum should be pure, both for the sake of uniformity and also because the See also:change of electrical resistance with temperature is greatly diminished by impurities. The observation of the fundamental coefficient, which is •00390 (or rather larger than the coefficient of expansion of a See also:gas) for the purest metal hitherto obtained, is one of the most delicate tests of the purity of the metal. In addition to the constancy and infusibility of the metal, a special advantage which is secured by the use of platinum is the close agreement of the thermodynamical See also:scale with the platinum scale of temperature, as defined by the See also:formula pt=See also:loo(R—Ro)/(RI-R0), . . (24) in which the See also:symbol pt stands for the temperature on the platinum scale centigrade, and R, R1 and Ro are the observed resistances of the thermometer at the temperatures pt, Too° and o° C. respectively. A platinum thermometer is generally arranged to read directly in degrees of temperature on the platinum scale, just as a See also:mercury thermometer is graduated in degrees of the mercury scale. The reduction to the scale of the gas thermometer is most conveniently effected by the difference formula t—pt=dt(t—loo)/io,000, . (25) in which d is a constant, called the difference-coefficient, the value of which for pure platinum is about 1.50, but varies slightly for different specimens. This formula was fi*st given by the writer as the result of a series of comparisons of different platinum wires with each other and with other metals, and also with an See also:air thermometer over the range o° to 625° C.

The platinum wire in these comparisons was enclosed inside the bulb of the air thermometer itself, and disposed in such a manner as to be at the mean temperature of the bulb in case the temperature was not quite See also:

uniform throughout (Phil. Trans. A. 1887, p. x6i). The formula was subsequently verified by C. T. Heycock and F. H. See also:Neville (Journ. Chem. See also:Soc. See also:February 1895), by the observation of a number of higher points up to the freezing-point of copper at To82° C., which they showed to agree with the most probable mean of all the best determinations by various methods of gas thermometry.

At still higher temperatures, beyond the See also:

present range of the gas thermometer, the writer has succeeded in obtaining presumptive See also:evidence of the validity of the same formula by comparison with the scales of the expansion and the specific heat of platinum, which appear to follow similar See also:laws (Phil. Mag. See also:December 1899). If we assume that the coefficient of expansion of platinum, the coefficient of increase of resistance, and the specific heat are all three linear functions of the temperature, we obtain results which are in agreement within the limits of See also:error of observation up to the fusing-point of platinum itself. The same formula has been independently verified by the comparison of platinum thermometers with the constant-See also:volume See also:nitrogen thermometer by Harker and Chappuis (Phil. Trans. A. 1900), working at the See also:International See also:Bureau at Sevres, over the range o° to 65a C, It has also been shown to satisfy very closely the observations on the variation of electrical resistance of other metals over wide ranges of temperature. Although the theoretical explanation of the formula has not yet been given, owing to our See also:ignorance of the true nature of electrical See also:conduction and of the molecular constitution of metals, it may be regarded from an empirical point of view as being one of the most accurately established of all thermometric formulae. It will be observed that it also represents the simplest possible type of divergence from the thermodynamical scale. 24. Methods and Apparatus.—The methods of electrical thermometry may be roughly classified under two heads as (I) deflection methods, in which the temperature is deduced from the observed deflection of a galvanometer; and (2) See also:balance methods, in which the resistance or the electromotive force is balanced against a known adjustable resistance or potential difference.

The former methods are most suitable for rough work and rapid See also:

reading, the latter for accurate measurements. In the practice of the deflection method it is customary to use a movable-coil galvanometer, the sensitiveness of which can be varied by varying the resistance in circuit, or by varying the stiffness of the suspension. The accuracy attainable is of the order of one-See also:half of 1 per cent. on the deflection, and is limited by variations of resistance of the galvanometer, and by the imperfect See also:elasticity of the suspension. In any case the scale of the galvanometer should be calibrated or tested for uniformity. In this See also:kind of work the thermocouple has the advantage over the resistance thermometer in that the latter requires an auxiliary See also:battery to See also:supply the current; but in many cases this is no disadvantage, because it permits a greater See also:latitude of See also:adjustment, and makes it possible to obtain greater power than with the thermocouple. In cases where it is desired to obtain greater accuracy with-out abandoning the quickness of reading which is the principal advantage of the deflection method, it is possible to combine the two methods by balancing part of the potential difference by means of a See also:potentiometer and using the galvanometer for the small changes only. In cases where the greatest accuracy is required, a very sensitive galvanometer should be used, and the whole of the potential difference should be balanced as nearly as possible, leaving very little to depend on the deflection of the galvanometer. The degree of sensitiveness and accuracy obtainable depends primarily on the delicacy of the galvanometer, on the power available, and on the steadiness of the conditions of experiment. For thermometry of precision the resistance thermometer possesses three very great advantages over the thermocouple: (I) The power available, owing to the use of a battery, is much greater; (2) it is possible completely to eliminate the errors due to accidental thermal effects by See also:reversing the battery; (3) the See also:Wheatstone See also:bridge method can be employed in See also:place of the potentiometer, so that the constancy of the battery is immaterial, and it is not necessary to use a See also:standard See also:cell. The conditions to be satisfied in the attainment of the greatest possible accuracy in the measurement of temperature by this method differ somewhat from those, which obtain in ordinary measurements of resistance, so that a special type of apparatus has been evolved for the purpose, a brief description of which will be given. 25. Compensated Bridge Apparatus.—It is necessary that the thermometer should be connected to the measuring apparatus by wires or " leads " of considerable length, generally at least two or three metres, in order to avoid exposing the galvanometer and resistance See also:box, or other delicate parts of the apparatus, to changes of temperature.

It is also essential that the leads should not be too thick or heavy, for convenience in handling and to prevent conduction of heat along the See also:

stem of the thermometer. The resistance of that part of the leads. which is exposed to variations of temperature necessarily changes, and would give rise to serious errors if it were not determined or compensated. The method now generally adopted in accurate work is to compensate the variationsof resistance of the leads by an exactly similar pair of dummy leads called the " compensator " and connected as shown diagrammatically in fig. 6. The battery, consisting of a single cell, with a rheostat and reversing See also:key in circuit, is connected to the terminals AB of the two equal resistance coils AG, GB, which See also:form the ratio arms of the balance. These coils must be carefully tested for equality of temperature-coefficient, and placed in close proximity to each other so as to be always at the same temperature. If they are interwound on the same See also:reel, they must be most carefully insulated from each other. In parallel circuit with the ratio coils are connected the compensator CC' and the balancing resistances C'E, on one See also:side of the bridge-wire EF, and the compensating resistances FP and the See also:pyrometer and leads PRP' on the other side. The galvanometer is connected to the point G between the ratio coils, and to the sliding contact D on the bridge-wire. Since the ratio coils are always equal, equal changes of resistance on either side of D are eliminated, and do not affect the balance. Thus the changes of the pyrometer leads PP' are balanced by the equal changes of the compensator leads CC' on the other side. As a further refinement, which is of some importance in delicate work, the ends of the compensator leads are connected by a See also:short piece of the same wire as the pyrometer coil.

For instance, in observing the variations of temperature of the See also:

steam in the cylinder of a steam engine at different points of the stroke with a very delicate thermometer made of wire one-thousandth of an inch in See also:diameter (Prot. Inst. C. E., vol. cxxxi. fig. 16, p. 23), the ends of the See also:fine wire attached to the thick leads could not follow the rapid variations of temperature, and it was found necessary to adopt this See also:device to eliminate the end-effect. It is also useful in other cases to eliminate the effect of conduction along the leads in cooling the ends of the fine wire coil. The balancing resistances C'E are made of some alloy such as manganin or platinum-silver, the resistance Rheostat Co/1R FIG. 6.—Diagram of Compensated Bridge Method. of which varies very little with change of temperature. Platinum-silver is probably the best material, as it can be perfectly annealed at a red heat without See also:risk of burning, and is then extremely constant. Unless the box can be kept at an absolutely constant and uniform temperature, which is not impossible but often inconvenient, it is necessary to allow for the change of resistance of the balancing coils C'E due to change in the temperature of the box.

The temperature of the coils cannot be accurately determined with a mercury thermometer unless they are immersed in oil, but even in that case it is necessary to know the temperature-coefficient of each individual coil. A more convenient and accurate method, which. eliminates the correction automatically, is to compensate each individual coil of the balancing coils C'E by a corresponding compensating coil at FP on the other side of the bridge-wire. The compensating coils are made of platinum, also annealed at a red heat, and each is placed in the box in close proximity to the coil it is intended to compensate. Each balancing coil and its compensator are tested together at various temperatures between to° and 3o° C., and are adjusted until their difference remains constant for any small variation of temperature in the See also:

neighbour-See also:hood of 20° C. This method of See also:compensation was applied by the writer in 1887, but has not been generally adopted on account of the labour involved in adjusting the coils. The See also:absolute values of the resistances are immaterial, but it is necessary to know the relative values with the greatest possible accuracy. For this reason it is preferable to arrange the resistances in the binary scale, each resistance being equal to twice the next smaller resistance, or to the sum of all the smaller resistances, the two smallest resistances being made equal. This arrangement permits the greatest accuracy of comparison in the simplest manner with the fewest observations. The bridge-wire EF provides a continuous scale for reading small changes of resistance. Any change of resistance of the pyrometer coil necessitates the See also:movement of the balance point D through an See also:equivalent resistance along the bridge-wire. The equivalent resistance of the bridge-wire per unit length of the attached scale is preferably adjusted, by means of a shunt shown in parallel with it in fig. 5, to be an exact submultiple of the smallest resistance coil.

It is usual also to adjust the resistances of the thermometers so that their fundamental intervals are convenient multiples of this unit, generally either too, 200, 500, or t000, so that the bridge-wire may read directly in degrees of temperature on the platinum scale. It is easy to get a scale of to cms. or more to the degree, and it is not difficult with a suitable galvanometer to read to the ten-thousandth part of a degree. The length of the bridge-wire itself need not be more than 20 or 30 cms., as the balancing resistances enable the scale to be indefinitely ex-tended. Thus the instrument possesses the great advantage over the mercury thermometer that the most open scale may be easily secured without unwieldy length, and without restricting the range of each thermometer. 26. Errors and Corrections.—It is most instructive to consider the errors and corrections involved in platinum thermometry on the same lines as those on which the corresponding errors of the mercury thermometer have already been treated. I. The changes of zero of the mercury thermometer arise chiefly from the small expansibility of mercury combined with the imperfect elasticity of the containing See also:

tube. In platinum thermometry the containing tube has nothing to do with the reading, and the effect of any possible See also:strain of the fine wire of the coil is minimized by its small dimensions and by the large temperature-coefficient of the increase of resistance, which is more than twenty times greater than the coefficient of apparent expansion of mercury in glass. It is not surprising, therefore, that the changes of zero of a platinum thermometer should be practically negligible, provided that the wire is not strained and contaminated with impurities. It is probable that with ordinary care the changes of zero due to exposure to any given limits of temperature are in all cases less than the limit of accuracy of observation, due to other causes at the extreme limit of the range considered. II.

The fundamental interval of each thermometer must be determined as usual by observations in See also:

ice and steam, and a correction must be applied by the method already described in the case of the mercury thermometer. The difference of the temperature of the steam from too° C. should be determined on the platinum scale by the approximate formula dpt1= •985dt1= .0362(H — 76o) — .000020 (H — 760)2 .. (26) IV. Stem Exposure.—The reading of a platinum thermometer with compensated leads depends only on the temperature of the coil of wire forming the bulb, and not on the temperature of the stem, provided that the See also:immersion is sufficient to avoid errors due to conduction or convection along the stem. It is desirable that the See also:top of the bulb should be immersed to a depth equal to from three to ten times the diameter of the tube, according to the accuracy required. V. Scale Correction.—The reduction to the thermodynamical scale may be effected, within the limits of probable error of the most accurate measurements at present available, by the very See also:simple difference formula (25) already given, over the whole range from —too° C. to -{-1too° C. This is in striking contrast with the mercury thermometer, which requires a cubic formula to See also:cover the range 0° to 200° C. with equal accuracy. The value of the constant d in the formula varies but little, provided that the wire be fairly pure and the thermometers properly constructed. In order to determine its value in any special case, it is best to take an observation at the boiling-point of See also:sulphur (S.B.P.) for temperatures above 0° C., or at that of See also:oxygen for temperatures below o° C. See also:clown to —zoo° C. It appears probable that there is a point of inflection in the See also:curve of resistance-variation of platinum and some other metals in the neighbourhood of -200° C., and that the formula does not apply accurately below this point. It has become the See also:custom to assume the boiling-point of sulphur (S.B.P.) under normal pressure to be 444.53° C., as determined by Callendar and Griffiths, using a constant-pressure air thermometer, and to take the See also:rate of change of temperature with pressure as '082° per mm. from See also:Regnault's observations.

According to experiments made at See also:

Kew See also:Observatory with platinum thermometers (Chree, Proc. R. S., 1900), the rate of change is somewhat larger than that given by Regnault's formula, namely, about '09o° per mm., and it appears desirable to determine this constant with greater accuracy. The difference between the above formulae reaches a tenth of a degree if the See also:barometer differs by 12 mm. from 76o mm. The uncertainty in the absolute boiling-point of sulphur, however, is probably somewhat greater than one-tenth of a degree, on account of the uncertainty of the expansion correction of the gas thermometer (Phil. Mag., December 1899). The thermodynamical correction of the gas thermometer, which amounts to half a degree at this point, is also to some extent uncertain, on account of the exteapolation. Provided, however, that some exact value of the S.B.P. is chosenfor reference, for the reduction of observations with platinum thermometers, the results so reduced will be strictly comparable, and can be corrected at any subsequent See also:time when the value of the S.B.P. is more accurately determined. The boiling-point of oxygen may be taken as -182.5° C. with sufficient approximation for a similar purpose. VI. See also:Calibration Correction.—The calibration of the resistance box and the bridge-wire corresponds to the calibration of the stem of the mercury thermometer, but the See also:process is much simpler for several reasons. It is more easy to obtain a uniform wire than a uniform tube.

The scale of the wire is much more open, it corresponds to a very small part of the whole scale, and the process of calibration is easier. One box when calibrated will serve for any number of thermometers of different ranges and scales, and covers the whole range of temperature (see CALIBRATION). 27. Electrical Precautions.—The platinum thermometer is so far See also:

superior to the mercury thermometer in all the points above enumerated that, if there were no other difficulties, no one would ever use a mercury thermometer for work of precision. In using a platinum thermometer, however, some electrical training is essential to obtain the best results. The manipulation and adjustment of a delicate galvanometer present formidable difficulties to the non-electrical observer. See also:Bad contacts, faulty connexions, and defective insulation, are not likely to trouble the practised electrician, but present endless possibilities of error to the tyro. A useful discussion of these and similar details is given in the See also:paper by Chree already referred to. Bad insulation of the pyrometer and connexions can easily be detected, in the compensated instrument already described, by disconnecting one of the C leads from the battery and one of the P leads from the bridge-wire. Under these conditions the galvanometer should not deflect if the insulation is perfect. Defective insulation is most likely to be due to See also:damp in the thermometer at low temperatures. This source of error is best removed by drying and hermetically sealing the thermometers.

Trouble from bad contacts generally arises from the use of plugs for the resistance coils. If plugs are used, they must be specially designed so as not to disturb each other, and must be well fitted and kept very clean. Mercury cups with large copper terminals, well amalgamated, as used with standard resistance coils, are probably the simplest and most satisfactory method of changing connexions. Accidental thermoelectric effects in the circuit are a possible source of error, as with the thermocouple, but they are always very small if the thermometer is properly constructed, and are relatively unimportant owing to the large E.M.F. available. In any case they may be completely eliminated by reversing the battery. The See also:

heating effect of the current through the thermometer is often negligible, but should be measured and allowed for in accurate work. With a current of •01 See also:ampere the rise of temperature should not exceed I lu or 1k, of a degree. With a delicate galvanometer it is possible to read to the ten-thousandth of a degree with a current of only •002 ampere, in which case the heating effect is generally less than i I,lGy of a degree. It can be very easily measured in any case by changing from one cell to two, thus doubling the current in the thermometer, and quadrupling the heating effect. The correction is then applied by subtracting one-third of the difference between the readings with one and two cells from the reading with one cell. The correction is always very small, if a reasonably sensitive galvanometer is used, and is frequently negligible, "especially in See also:differential work, which Is one of the most fruitful applications of the platinum thermometer. 28.

Construction of Thermometers.—One of the See also:

chief advantages of the platinum thermometer for See also:research work is the endless variety of forms in which it may be made, to suit the particular exigencies of each individual experiment. It is peculiarly suited for observing the See also:average temperature throughout a length or space, which is so often required in See also:physical experiments. For this purpose the wire may be disposed in a straight length, or in a See also:spiral, along the space in question. Again, in observing the temperature of a gas, the naked wire, on account of its small See also:mass and extremely low radiative power, is far superior t8 any mercury thermometer. The commonest form FIG. 7.—of platinum thermometer (fig. 7), and the most Platinum suitable for See also:general purposes, contains a coil B from Thermometer. 4 in. to 2 in. See also:long, See also:wound on a See also:cross of thin See also:mica, and enclosed in a tube, about ; to s in. in diameter, of glass or See also:porcelain according to the temperature for which it is required. The pyrometer leads and the compensator leads are insulated and kept in place by passing through mica disks fitting the tube, which serve also to prevent convection currents up and down the tube. The protecting tube of glass or porcelain is fitted with a wooden See also:head A carrying four insulated terminals, PP, CC, to which the pyrometer e THERMOMETRY 833 of short periodi giving a-contittuotta:tecord en'a«in vmgrphoto graphic film.' When 'the 'See also:flame 'reaehed ttie Wire •the' teitn tare See also:rose 1200° C; in about of' a second, which illustrates the' order of sensitiveness attainable with a. fine wire of this See also:size. O. R.

Lummer and E. See also:

Pringsheim, in their measurements of the ratio of the specific heats of gases by observing the fall of temperature due to sudden expansion, employed a very thin See also:strip of See also:foil with the See also:object of securing greater sensitiveness. This was a somewhat doubtful expedient, because such a strip is extremely fragile and liable to be injured by air currents, and because the sensitiveness is not as a See also:matter of fact appreciably improved, whereas the See also:radiation error is increased in See also:direct proportion to the surface exposed. One of the principal See also:sources of error in employing a short See also:loop of fine wire for observing rapidly varying temperatures is that the ends of the loop close to the thick leads are affected by conduction of heat to or from the leads, and cannot follow the rapid variations of temperature. This error may be readily avoided by the method. first employed by Callendar and Nicolson, of connecting the compensating leads with a short length of the same fine wire. The end effect is then eliminated by observing the difference of resistance between two loops of different lengths. Thermocouples of very fine wire have also been employed for similar measurements, but they are more difficult to make than the simple loop of one wire, and the sensitiveness attainable is much less, owing to the small E.M.F. of a single thermocouple. 31. Radiation Thermoscopes.—For measuring the intensity of radiation, some form of thermometer with a blackened bulb or sensitive See also:area is employed. It is assumed that the rise of temperature of the thermometer is approximately proportional to the intensity of the radiation according to See also:Newton's See also:law of cooling (see HEAT) for small differences of temperature. A mercury maximum thermometer with a small blackened bulb is still very generally employed in meteorological observatories for registering the maximum See also:solar radiation. But the indications are liable to error and very difficult to interpret, and an instrument of this type is not sufficiently sensitive or See also:quick in action for weak sources of radiation.

See also:

Sir See also:John See also:Leslie employed an air thermoscope, similar to that of Galileo (HEAT, fig. 1), with a blackened bulb. This has the advantage of a small capacity for heat, and is still employed in various forms for demonstration purposes, but is not sufficiently sensitive for accurate work. Electrical thermometers are now generally employed on account of their superior sensitiveness, and also on account of the greater facility of See also:adaptation for the requirements of each particular experiment. The most See also:familiar instrument is M. See also:Melloni's thermopile, which is built up of a number of small bars of See also:antimony and See also:bismuth, or other alloys of high thermoelectric power, arranged in the form of a See also:cube with alternate junctions on opposite faces. When connected to a galvanometer of suitable resistance, this arrangement gives a high degree of sensitiveness on account of the multiplication of couples, but owing to the large mass of metal involved in its construction it takes a considerable time to acquire a steady See also:state. This defect has been remedied in the radiomicrometer of C. V. Boys (Phil. Trans., 1888, 18o A, p. 159) by employing a single junction attached to a small disk of very thin copper.

The See also:

free ends of the See also:minute bars forming the couple are connected to a loop of thin copper wire suspended by a fine See also:quartz fibre between the poles of a magnet. This arrangement forms a very delicate galvanometer and gives the maximum sensitiveness attainable with a single couple, since all unnecessary connecting wires are avoided. It is incomparably quicker and more dead-See also:beat in action than the ordinary thermopile, but has the disadvantage that it must be set up permanently on a steady support and the radiation brought to it In a See also:horizontal direction. An instrument of similar delicacy is the See also:radiometer, the action of which depends on the repulsive effect of the residual gas in a nearly perfect vacuum on a delicately balanced See also:vane suspended by a fine fibre. An instrument of this type was first constructed by Sir See also:William See also:Crookes (see RADIOMETER) ; the instrument was applied to radiation measurements, and its sensitiveness greatly improved by E. F. See also:Nichols. It requires a very steady mounting, like the radiomicrometer, but has the additional defect that the radiation must be introduced through a window, which may give rise to selective absorption. Other varieties of thermopile, in which the sensitive parts are constructed, as in Boys' radiomicrometer, so as to have a very small capacity, but are connected like the ordinary pile to a See also:separate galvanometer, have been employed by See also:Lord See also:Rosse for observations of lunar heat and by W. H. See also:Julius and Callendar for the solar See also:corona. In cases where the radiation can be concentrated on a very small area, such as the receiving disk of the radiomicrometer, the thermoelectric method is probably the most sensitive.

But if there is no restriction as to the area of the receiving surface, considerable advantage may be gained in convenience of manipulation, without loss of sensitiveness, by the electric resistance method. An instrument of this type was first employed by S. P. See also:

Langley (Proc. Amer. Acad., 1881, 16, p. 342) under the name of the bolo-See also:meter, by which it has since been known. The sensitive surface is made in the form of a blackened grid of thin metallic foil, gene-rally platinum coated with platinum See also:black, connected in one of the and compensator leads are respectively connected, and whb h serve to connect the instrument to the measuring apparatis. For work of the highest precision these terminals are often omitted, and the leads are directly soldered to a flexible See also:cable in order to avoid possible errors from thermoelectric effects and changes of resistance of the See also:screw terminals. For temperatures above 500° C. the protecting tube must be of porcelain, and the leads of platinum throughout that part of the tube which is exposed to high temperatures. For See also:lower temperatures a tube of hard glass and leads of copper or silver may be employed, but it is better in any case to make the lower part of the leads of platinum in order to diminish the conduction of heat along the stem. For laboratory work a tube 30 or 40 cm. in length usually suffices, but for large furnaces the length of the protecting tube is often 5 to 10 ft.

In the latter case it is usual to protect the porcelain tubes with an See also:

external See also:steel tube, which may be removed for delicate measurements. 29. Special Forms of Thermometer.—In the measurement of linear expansion it is a great advantage to employ a thermometer with the bulb or sensitive portion equal in length to the See also:bar or See also:column under test, so as to obtain the mean temperature of the whole length. In measuring the linear expansion of a standard See also:metre or yard, a fine platinum wire enclosed in a glass capillary, or other-See also:wise insulated, is employed, its length being equal to that of the bar. The same method has been applied by Callendar (Phil. Trans. A, 1887) and See also:Bedford (Phil. Mag., 1898) to the expansion of glass and porcelain at high temperatures, employing a fine wire sup-ported along the See also:axis of the tube under test. An equivalent method, applied to the expansion of See also:silica by Callendar, is to enclose a See also:rod of the material inside a platinum tube which is heated by an electric current. This is a very rapid and convenient process, since the mean temperature of the rod must be equal to that of the enclosing tube. Any temperature up to the melting-point of platinum is readily obtained, and easily regulated. The temperature may be obtained by observing either the resistance of the platinum tube or its linear expansion.

Either method may also be employed in J. Joly's meldometer, which consists of an electrically heated strip for observing the melting-points of minerals or other substances in small fragments. In observing the temperature of a long column of mercury, as in the method of equilibrating columns for deter-See also:

mining the absolute expansion of mercury, a platinum thermometer with a bulb equal in length to the column may similarly be employed with advantage. The application is here particularly important because it is practically impossible to ensure perfect uniformity of temperature in a See also:vertical column, 6 ft. or more in length, at high temperatures. 30. Sensitive Thermometers.—Where quickness of reading is essential, the mercury thermometer, or the tube form of electric thermometer, is unsuitable. In cases where the thermometer has to be immersed in a conducting liquid or See also:solution, the fine wire forming the bulb may be insulated by enclosing it in a coiled glass capillary. This method has been employed by Callendar and See also:Barnes and by Jaeger, but the instrument is necessarily fragile, and requires careful handling. For non-conducting liquids or gases the See also:bare wire may be employed with great advantage. This is particularly important in the case of gases owing to the extreme sensitiveness thus obtained and the almost complete See also:immunity from radiation error at moderate temperatures. Thermometers constructed in the form of a See also:flat grid of bare wire mounted on a mica and ebonite See also:frame have been employed by H. See also:Brown (Proc.

R. S., 1905, B 76, p. 124) for observing the temperature of leaves and of air currents to which they were exposed. They have also been employed for observing the air-temperature for meteorological purposes in See also:

Egypt and See also:Spain with very satisfactory results (Proc. R. S., 1905, A 77, p. 7). The fine wire, owing to its small size and See also:bright metallic surface, very rapidly acquires the temperature of the air, and is very little affected by radiation from surrounding See also:objects, which is one of the chief difficulties in the employment of mercurial thermometers for the observation of the temperature of the air. For the observation of rapidly varying temperatures, such as those occurring in the cylinder of a gas- or steam-engine, an electrical thermometer with very fine wire, of the order of .001 in. diameter is practically the only instrument available. The temperature at any particular moment may be obtained by setting a See also:mechanical contact-maker to close the circuit at the desired point. The sensitive part of the thermometer consists simply of a loop of fine wire from half an inch to an inch long, connected by suitable leads to the measuring apparatus as employed by Burstall (Phil. Mag., See also:October 1895) in the gas-engine, and Callendar and Nicolson (Proc.

Inst. C. E., 1898) in the steam-engine. The See also:

explosion temperatures cannot be satisfactorily measured in a gas-engine in this manner, because the radiation error at high temperatures is excessive unless the wire is very fine, in which case it is very soon melted even with weak mixtures. Callendar and Dalby accordingly devised a mechanical See also:valve (Proc. R. S., A 8o, p. 57) for exposing the thermometer only during the See also:admission and See also:compression strokes, and have deduced the actual explosion temperatures from the See also:indicator See also:diagram. B. See also:Hopkinson (Proc. R. S., A 77, p.

End of Article: ELECTRICAL

Additional information and Comments

There are no comments yet for this article.
» Add information or comments to this article.
Please link directly to this article:
Highlight the code below, right click, and select "copy." Then paste it into your website, email, or other HTML.
Site content, images, and layout Copyright © 2006 - Net Industries, worldwide.
Do not copy, download, transfer, or otherwise replicate the site content in whole or in part.

Links to articles and home page are always encouraged.

[back]
ELECTRIC WAVES
[next]
ELECTRICAL (or ELECTROSTATIC) MACHINE